Tank Level
Roll Diameter
Open Channel Flow
Tough. by Design
The ToughSonic name says it all:
Type 316 stainless steel provides superior corrosion and chemical resistance, resists pitting, and is often applied in salt water environments.
Sensors can be assembled with custom cables or connectors. Serial data-only models are available for remote monitoring and other serial data-only applications.
Smart. Engineering
ToughSonic sensors have the smarts to:
Senix invented PC-configurable “smart sensors” in 1990 and has improved them ever since, giving you get the benefits of years of continuous improvement!
Flexible. Outputs
PLUS EVERY ToughSonic Ultrasonic Sensor has serial data for SenixVIEW setup or user application:
Connected. SenixVIEW Software
SenixVIEW is included at no charge, runs on a Windows PC and connects to sensors via a serial data port. Our Setup Kits provide everything needed to connect through a USB port, including power supply, sensor-PC interface and cables. SenixVIEW is not required but adds powerful configuration, test and management capability.
Part No. | Outputs |
TSPC-30S1-485 | 2 + RS-485 |
TSPC-30S1-485A | RS-485 only * |
TSPC-30S1-232 | 2 + RS-232 |
TSPC-30S1-232A | RS-232 only * |
Part No. | Outputs |
TSPC-N1S1-485 | 2 + RS-485 |
TSPC-N1S1-485A | RS-485 only * |
TSPC-N1S1-232 | 2 + RS-232 |
TSPC-N1S1-232A | RS-232 only * |
Specifications
Maximum Range | 14 feet (4.3 meters) |
Optimum Range | 10 Feet (3 meters) |
Deadband | 0-4 in (0-102 mm) |
Temperature | -40° to 158° F (-40° to 70° C) |
Humidity | 0 to 100% operating |
Protection | NEMA-4X, NEMA 6P, IP68 |
Transducer | Ruggedized piezoelectric |
Compensation | Temperature compensated (selectable in SenixVIEW) |
Resolution | Serial data: 0.0034 in. (0.086 mm) Analog steps: 4099 (0-10 VDC), 3279 (4-20 mA) |
Repeatability | Nominal 0.2% of range @ constant temp. Affected by target, distance, environment |
Update Rate | 20 Hz (50 ms), SenixVIEW adjustable; affected by SenixVIEW filter selections |
*Specifications are subject to change without notice.
Outputs
Output #1 | Default: 4-20 mA; SenixVIEW configurable Alternate: Configure it as a switch output |
Output #2 | Default: Voltage, SenixVIEW configurable Alternate: Configure it as a switch output |
Voltage Output | 0-10, 0-5 VDC or SenixVIEW configurable 10 mA maximum |
4-20 mA Current Loop |
Current sourcing, SenixVIEW configurable Maximum loop resistance 450Ω |
Switch Output(s) | Output #1 and/or #2 can be a switch Each can be sinking (NPN) or sourcing (PNP) Max ratings: 150 mA @ 40 VDC Each has adjustable setpoint, polarity, hysteresis, window, time delays and more |
RS-232 or RS-485 |
Modbus & streaming protocols 9600-115200 baud (configurable) 8 data bits, 1 stop, no parity RS-485 permits multi-sensor networks Part number determines interface |
SYNC feature | Permits multiple sensors to operate in close proximity without cross-talk Not usable concurrently with serial data |
Mechanical
Housing | 316 stainless steel for corrosion resistance Usable in salt water, H2S environments |
Mounting (30 mm) |
Through hole in bracket or panel Two jam nuts included Stainless & nylon brackets available Adapters to 1-1/2 in and 2 in NPT available |
Mounting (1-in NPT) |
Typically for tank mounting Mates with 1-in NPT female thread |
Attached Cable | 6.5 feet (2 meters), PUR jacketed Custom lengths available Standard models: 6-wire shielded + drain Serial data only models: 4-wire + drain |
Total Weight | 30 mm: 10.4 oz. (0.29 kg) 1-in NPT: 14.2 oz. (0.40 kg) Weights include 2 m cable |