Maximum Range 35 Feet (10.7 Meters)
Water / Wastewater
Chemicals
Tank Level
Tough. by Design
The ToughSonic name says it all:
Injection moulded PVDF (Kynar) for superior chemical resistance
Kynar® is a registered tradename of Arkema Corporation
∗ Measurement is unreliable when submersed
Sensors can be assembled with custom cables or connectors. Serial data-only models are available for remote monitoring and other serial data-only applications.
Smart. Engineering
ToughSonic sensors have the smarts to:
Senix invented PC-configurable “smart sensors” in 1990 and has improved them ever since, giving you get the benefits of years of continuous improvement!
Flexible. Outputs
PLUS EVERY ToughSonic Ultrasonic Sensor has serial data for SenixVIEW setup or user application:
Connected. SenixVIEW Software
SenixVIEW is included at no charge, runs on a Windows PC and connects to sensors via a serial data port. Our Setup Kits provide everything needed to connect through a USB port, including power supply, sensor-PC interface and cables. SenixVIEW is not required but adds powerful configuration, test and management capability.
ToughSonic CHEM 35
Top or Bottom Mounted
Manual
Data Sheet
Arkema Kynar Chemical Resistance Chart
3D Models
Part No. | Outputs |
LVL-500-485 | 5 + RS-485 |
LVL-500-485A | RS-485 only * |
LVL-500-232 | 5 + RS-232 |
LVL-500-232A | RS-232 only * |
Specifications
Maximum Range | 35 feet (10.7 meters) |
Optimum Range | 12 inches to 25 feet (30.5 cm to 7.6 meters) |
Deadband | 0-12 in (0-30.5cm) |
Temperature | -40° to 158° F (-40° to 70° C) |
Humidity | 0 to 100% operating |
Protection | NEMA-4X, NEMA 6P, IP68 |
Transducer | Chemically isolated piezoelectric |
Compensation | Temperature compensated SenixVIEW selected options |
Resolution | Serial data: 0.0034 in. (0.086 mm) Analog steps: 4099 (0-10 VDC), 3279 (4-20 mA) |
Repeatability | Nominal 0.2% of range @ constant temp. Affected by target, distance, environment |
Update Rate | 20 Hz (50 ms), SenixVIEW adjustable; affected by SenixVIEW filter selections |
*Specifications are subject to change without notice.
Outputs
Voltage Output | 0-10, 0-5 VDC or SenixVIEW customized Maximum output current 10 mA |
Current Loops (x 2) |
Two 4-20 mA current loops: Current sourcing and current sinking Max loop resistance 450 ohms each SenixVIEW customized Both share calibration parameters |
Switches (x 2) |
Two switches, SenixVIEW customized 150 mA max @ 40 VDC max SenixVIEW selected as sinking (NPN) or sourcing (PNP) Adjustable setpoint, polarity, hysteresis, ON timing, OFF timing |
Serial Data Interface | Modbus & streaming protocols 9600-115200 baud (configurable) 8 data bits, 1 stop, no parity RS-485 permits multi-sensor networks Part number determines interface |
Mechanical
Housing | Injection moulded, chemically resistant Polyvinylidene fluoride (PVDF) Also known as Kynar, a registered tradename of Arkema Inc. |
Mounting | Top mount: 1-inch NPT (options available) Bottom: 2 in.straight, fits NPT or BSP Bottom nut UA-NUT20-PV (order separately) |
Cable | Potted into sensor, pigtail termination 6.5 feet (2 meters), PUR jacketed Custom lengths available Standard models: 9-wire shielded + drain Serial data-only models: 4-wire + drain |
Weight | 24.7 oz. (0.70 kg) Weight includes 6.5 ft (2 meter) cable |