Displays and Process Meter Accessories

Read Levels and Control Processes in One Device

Precision Digital Enclsoure PDA2301 with one meter installedAccess to level information or your tanks or dimensional data in your process line is easy with these displays. Compact and powerful, they can recalculate sensor data into meaningful units, such as gallons or percent full, and use those units to control other processes. Choose serial or analog inputs, and one or two line displays.

Serial displays can monitor a single sensor or up to 32 sensors in a network using any ToughSonic RS-485 sensor model. Displays can also attach and “snoop” the network to mirror readings at multiple locations or to display particular sensor values. Relays, alarms, and isolated analog outputs offer additional process control options.

Input data can also be linearized to handle applications such as converting the liquid height in a horizontal cylindrical tank to volume in gallons, or the height of water in a weir to flow rate.

UA-DBOX-LP1821

UA-PD865

UA-PD6000

UA-PD6080





PD865 Display and Process Controller for ToughSonic Ultrasonic Sensors PD6000 analog display and process controller for ToughSonic ultrasonic sensors.





Mounting Self-contained NEMA 4X Panel Mount, 1/8 DIN
optional enclosures
Panel Mount, 1/8 DIN
optional enclosures
Panel Mount, 1/8 DIN
optional enclosures





Sensor Input Analog
4-20 mA or 0-10 V
Serial
Serial RS-485 Modbus
Analog
0-20, 4-20 mA
+/-10, 0-5, 1-5, 0-10 V
Serial and/or Analog
Serial RS-485 Modbus
2 analog (4-20 mA, ±10 V)





Power Input 86-260 VAC 50/60 Hz
(others available)
85-265 VAC 50/60 Hz
(others available)
85-265 VAC 50/60 Hz
(others available)
85-265 VAC 50/60 Hz
(others available)





Connect to 1 Sensor Poll 1 to 8, display 1 1 Sensor 1 to 16 sensors





Sensor supply 24 VDC @ 100 mA Isolated 24 VDC ±10% @ 200 mA max Isolated 24 VDC ±10% @ 200 mA max Isolated 24 VDC ±10% @ 200 mA max





Analog Outputs None (Option #1: 4-20 mA) Isolated 4-20 mA Optional isolated 4-20 mA Optional isolated 4-20 mA





Relays 2 relays (Option #1: 1 relay) 2 standard + 2 optional Optional 2 or 4 relays Optional 2 or 4 relays





Pump control Yes Yes Yes Yes





Temperature
Humidity
Ingress
Operating -20 to 70ºC
5 to 90% non-condensing
Enclosure: NEMA 4X, IP65
Operating -40 to 65ºC
0 to 90% non-condensing
Panel NEMA 4X, IP65
Operating -40 to 65ºC
0 to 90% non-condensing
Panel NEMA 4X, IP65
Operating -40 to 65ºC
0 to 90% non-condensing
Panel NEMA 4X, IP65

What our customers say…

U.S. NOAA logo

We use the sensors to measure water during the summer, ice and snow during the winter.  They have been working very well.  The waterproof SS case you put it in is a major plus during extreme weather events.  Love the PC feature.

Sensors Compatible With All Displays

Sensors Compatible With Serial-Input Displays Only

Sensors Compatible With Analog-Input Displays Only

Articles and News